Magnamed Fleximag ventilator
- Touch screen LCD 15 inch (adult, pediatric, neonatal) PRVC Mode
- Tidal Volume 2-300ml
-Alarm System
- Internal BATTERY up to 3hr
- History for the latest 24hr
- all accessories
PHYSICAL CHARACTERISTICS:-
• DISPLAY - Color GRAPHIC LCD with touch screen 15inch.
• Keys: stand by; Hold Insp; Hold Exp; O2 100%; Manual Insp; Lock
• Measurement of pressure, flow, the concentration of oxygen in the breathing Ventilation modes: PRVC VCV PCV PLV V-SIMV+PS P-SIMV+PS PSV DUALPAP(2) CPAP NIV
• circuit. Barometric and pipeline pressure measurement
• Loudspeaker to indicate alarms and alerts
• External Inlet 100-240VAC – 50/60Hz
• On-Off button • Galvanic O2 Sensor Distal Flow Sensor (Hot Wire)
• Last Adjustments Start-Up
• Nebulizer Sincronized with Inspiration and Volume Compensation
• Traqueal Gas Insuflation (TGI)
• 100% O2 to the automatic system of aspiration
• Automatic gas commutation in case of fault of oxygen or air compressed
• Automatic Adjustment of Parameters According Patient Weight Trend
• Weight: 18KG
• Dimension: 1335mm X 453mm X 542mm
Internal BATTERY: Internal Li-Ion Battery 11.8Vdc;
Intelligent Battery Charger
Internal Battery Autonomy: 180min
Adjustments
Specifications Parameter:
Tidal Volume: 2 to 3000ml.
Respiratory Frequency: 0 to 180bpm.
Rise Time: 0 to 2.0s
Pause: 10 to 30s
Inspiratory Pressure: 0 to 120cm
H2O PS
- Pressure Support: 0 to 120cm
H2O PEEP: 0 to 50cm
H2O Pressure
Trigger: 0.0 to -20cm
H2O Flow
Trigger: 0.0 to 30L/min Cycling
PS: 5 to 80% FIO2: 21 to 100%
Inspiratory Time: 0.05 to 30s Inspiratory
Flow Wave: Square, Decelerate, Accelerate, Sine.
CPAP: 1 to 50cmH2O.
Pressure High: 1 to 60cmH2O
Pressure Low: 0 to 40cmH2O
Time High: 0.2 to 59.8s
Time Low: 0.2 to 59.8s
I:E Ratio: 1:599 to 10:1
Backup Ventilation: in all spontaneous modalities.
Inspiratory Flow: 0 to 180L/min
Nebulizer: synchronized during inspiratory time 5 to 8 L/min.
Tracheal Gas Insufflation (TGI)
– deliver O2 100% during expiratory time.
Alarm System and Safety:
•Initial Auto Test -Leakage test
•Automatic calibration Anti-asphyxiation Valve
•Safety Relief Valve 100hPa -Alarm Indicator Light (LED) with High Viewing
•HIGH/LOW Pressure: OFF, 0 to 120cmH2O -HIGH/LOW PEEP: OFF , 0 to 80cmH2O
•HIGH/LOW Volume: OFF, 0 to 3000ml -HIGH/LOW Respiratory Frequency: OFF, 0 to 200bpm
•HIGH/LOW Minute Volume:OFF, 0 to 99L/min -FIO2: OFF; 21 to100%
•Apnea: OFF; 5 to 60s -Automatic Adjustment of Alarms: OFF; 10% , 20% , 30%.
•Low Battery. - Air/ O2 Low Pressure alarm.
•Disconnection/Obstruction of Respiratory Circuit.
-AC Input Fail.