Magnamed Fleximag ventilator- Touch screen LCD 15 inch (adult, pediatric, neonatal)

Availability: In Stock Seller : Medical Market

Magnamed Fleximag ventilator

- Touch screen LCD 15 inch (adult, pediatric, neonatal) PRVC Mode

- Tidal Volume 2-300ml

-Alarm System

- Internal BATTERY up to 3hr

- History for the latest 24hr

- all accessories

PHYSICAL CHARACTERISTICS:-

• DISPLAY - Color GRAPHIC LCD with touch screen 15inch.

• Keys: stand by; Hold Insp; Hold Exp; O2 100%; Manual Insp; Lock

• Measurement of pressure, flow, the concentration of oxygen in the breathing Ventilation modes: PRVC VCV PCV PLV V-SIMV+PS P-SIMV+PS PSV DUALPAP(2) CPAP NIV

• circuit. Barometric and pipeline pressure measurement

• Loudspeaker to indicate alarms and alerts

• External Inlet 100-240VAC – 50/60Hz

• On-Off button • Galvanic O2 Sensor Distal Flow Sensor (Hot Wire)

• Last Adjustments Start-Up

• Nebulizer Sincronized with Inspiration and Volume Compensation

• Traqueal Gas Insuflation (TGI)

• 100% O2 to the automatic system of aspiration

• Automatic gas commutation in case of fault of oxygen or air compressed

• Automatic Adjustment of Parameters According Patient Weight Trend

• Weight: 18KG

• Dimension: 1335mm X 453mm X 542mm

Internal BATTERY: Internal Li-Ion Battery 11.8Vdc;

Intelligent Battery Charger

Internal Battery Autonomy: 180min

Adjustments

Specifications Parameter:

Tidal Volume: 2 to 3000ml.

Respiratory Frequency: 0 to 180bpm.

Rise Time: 0 to 2.0s

Pause: 10 to 30s

Inspiratory Pressure: 0 to 120cm

H2O PS

- Pressure Support: 0 to 120cm

H2O PEEP: 0 to 50cm

H2O Pressure

Trigger: 0.0 to -20cm

H2O Flow

Trigger: 0.0 to 30L/min Cycling

PS: 5 to 80% FIO2: 21 to 100%

Inspiratory Time: 0.05 to 30s Inspiratory

Flow Wave: Square, Decelerate, Accelerate, Sine.

CPAP: 1 to 50cmH2O.

Pressure High: 1 to 60cmH2O

Pressure Low: 0 to 40cmH2O

Time High: 0.2 to 59.8s

Time Low: 0.2 to 59.8s

I:E Ratio: 1:599 to 10:1

Backup Ventilation: in all spontaneous modalities.

Inspiratory Flow: 0 to 180L/min

Nebulizer: synchronized during inspiratory time 5 to 8 L/min.

Tracheal Gas Insufflation (TGI)

– deliver O2 100% during expiratory time.

Alarm System and Safety:

•Initial Auto Test -Leakage test

•Automatic calibration Anti-asphyxiation Valve

•Safety Relief Valve 100hPa -Alarm Indicator Light (LED) with High Viewing

•HIGH/LOW Pressure: OFF, 0 to 120cmH2O -HIGH/LOW PEEP: OFF , 0 to 80cmH2O

•HIGH/LOW Volume: OFF, 0 to 3000ml -HIGH/LOW Respiratory Frequency: OFF, 0 to 200bpm

•HIGH/LOW Minute Volume:OFF, 0 to 99L/min -FIO2: OFF; 21 to100%

•Apnea: OFF; 5 to 60s -Automatic Adjustment of Alarms: OFF; 10% , 20% , 30%.

•Low Battery. - Air/ O2 Low Pressure alarm.

•Disconnection/Obstruction of Respiratory Circuit.

-AC Input Fail.