Advanced Vital Signs Monitor RVS 100 - by Riester

Product Details:

- 3 measurement modes (Monitor, Spot-check, Triage).

- High-sensitivity 8” TFT colour touch screen with self-explanatory user interface and integrated help function.

- Displays SYS, DIA, MAP, Pulse, Temp, Plethysmogram.

- Clinical grade NIBP* including averaging mode.

- Programmable NIBP averaging mode (2-5 readings).

- Riester, Masimo* or Nellcor* Oximax SpO2.

- Predictive Thermometer (Filac 3000).

- Connectivity with the EMR - follows the HL7 standard.

- LAN Connectivity as standard.

- Programmable alarms (audible, visible) with 3 priority levels.

- Supports nurse call RJ11 port.

- Available as wall, desk and floor model.

- Can be expanded to wall diagnostic station.

- Internal memory for 5,000 measurements.

- Lithium-ion battery with up to 17 hours ON time (*includes neonate mode).

Options:

- Thermal printer (internal)

- Barcode reader

- Mobile stand including basket for storage (cuffs, sensors, cables) - WiFi - Accessories supplied with monitor - NIBP extension tube - 2 cuffs (adult & adult large incl. connectors) - SpO2 sensor adult - SpO2 extension cable - Oral temperature probe - Probe cover Technical Data: Monitor Power Supply: 100 – 240 V AC, 50/60 Hz Battery: Lithium-Ion battery, rechargeable, 10.8 V DC, 6,600 mAh, Charging time to a 100%: 6 hours, Operating time approx. 11 hours (new and fully charged battery at 25°C ambient temperature with connected SpO2, Temp, and NIBP on AUTO mode (15 minutes interval)) Low battery indicator Charging battery indicator Dimensions Monitor: L x H x W: 303 x 230 x 110 mm (11.93 x 9.06 x 4.33 in) Weight: 3.60 kg (7.94 lb) including temp module, printer Dimensions Basket: L x H x W: 270 x 225 x 200 mm (10.63 x 8.86 x 7.88 in) Alarm: Visible LEDs (Yellow, Red, Blue, Green, Orange) Audible Speaker Gives audible alarm, QRS tone Supports Pitch Tone and multi-level volume Alarm tones meet the requirement of IEC 60601-1-8. Alarm Pressure: 45 dB to 85 dB test distance is 1 meter from the tone. Ports: 1 x AC power inlet 1 x standard RJ45 interfaces.100 BASE-TX, IEEE 802.3 4 x USB ports 1 x Equipotential grounding point 1 x RJ11 connector for nurse call DC out port 15V/1.2 A Clinical-grade NIBP (non-invasive blood pressure) Clinical-grade NIBP (non-invasive blood pressure) Measuring method: automatic oscillometric Measurement range: Adult SYS 30 – 270 mmHg, DIA 10 – 220 mmHg, MAP 20 – 235 mmHg Pediatric SYS 30 – 235 mmHg, DIA 10 – 220 mmHg, MAP 20 – 225 mmHg Neonate SYS 30-135 mmHg, DIA 10-110 mmHg, MAP 20-125 mmHg Cuff pressure range: 0 – 280 mmHg Resolution: 1 mmHg Pressure accuracy: Static ±3 mmHg Clinic ±5 mmHg, standard deviation ≤ 8 mmHg Pulse rate range: 40 – 240 bpm Pulse rate accuracy: 1 bpm Initial inflation pressure: Adult 160 mmHg, Pediatric 130 mmHg, Neonate 75 mmHg Double overpressure protection (hardware and software) Adult 297 ± 3 mmHg, Pediatric 252 ± 3 mmHg , Neonate 147 ± 3 mmHg Alarm range: SYS 0 – 300 mmHg DIA 0 – 300 mmHg MAP 0 – 300 mmHg Riester SpO2 Measurement range: 0 – 100% Resolution: 1% Accuracy: ±2% (70 to 100%) ±3% (40% to 69%) Unspecified (0% to 39%) Alarm range: 0 – 100% Average time: 4 sec, 8 sec, 16 sec Pulse rate: Measurement range: 20 – 250 bpm Resolution: 1 bpm Accuracy: ±1% or ±1 bpm whichever is greater Nellcor SpO2 Measurement range: 0-100% Resolution: 1% Accuracy: 70 – 100%: ±2% (adult, pediatric) 70 – 100%: ±3% (neonate) Unspecified (0 – 69%) Alarm range: 0 – 100% Average time: 8 sec, 16 sec Pulse rate: Measurement range: 20 – 300 bpm Resolution: 1 bpm Accuracy: 20 – 250 bpm: ±3 bpm 251 – 300 bpm: unspecified Masimo SpO2: Measurement range: 0 – 100% Resolution: 1% Accuracy: 70 – 100%: ±2% (adult, pediatric, non-motion conditions) 70 – 100%: ±3% (neonate, non-motion conditions) 70 – 100%: ±3% (motion conditions) 0 – 69%: unspecified Average time: 2 – 4 sec, 4 – 6 sec, 8 sec, 10 sec, 12 sec, 14 sec, 16 sec Pulse rate: Measurement range: 25 – 240 bpm Resolution: 1 bpm Accuracy: ±3 bpm (non-motion conditions) ±5 bpm (motion conditions) Predictive thermometer: Oral ( Quick Mode ) non-fever temps: 3-5 seconds fever temps: 8-10 seconds Oral ( Standard Mode ): 6-10 seconds Axillary Mode: 8-12 seconds Rectal Mode: 10-14 seconds Direct Mode (all sites): 60-120 seconds Measurement accuracy: 35.5ºC - 42ºC (95.9°F – 107.6°F) Direct Mode (all sites): ±0.1ºC (±0.2ºF) Standard Prediction Mode (all sites): ±0.1ºC (±0.2ºF) Quick Prediction Mode (oral only): ±0.3ºC (±0.5ºF)

There Are No Reviews Yet

This Product Does Not Have a Catalog File